Study shows device significantly reduces blood draw contamination, patient risk

University of Nebraska Medical Center News Jun 01, 2017

A study at the University of Nebraska Medical Center (UNMC) found that a novel device can significantly reduce contamination of blood cultures, potentially reducing risky overtreatment and unnecessary use of antibiotics for many patients. This approach could also substantially reduce healthcare costs, according to the study.

Lead author of the study was Mark Rupp, MD, professor and chief of the UNMC Division of Infectious Diseases and medical director of the Department of Infection Control & Epidemiology at Nebraska Medicine, UNMC’s hospital partner.

With traditional blood draws, about 30 to 40 percent of patients with contaminated blood cultures are prescribed antibiotics unnecessarily. This contributes to antibiotic resistance and undermines nationwide efforts to improve antimicrobial stewardship. A large number of patients get another, unnecessary blood draw. For many patients the risks include an extended hospital stay and potential side effects of antibiotics.

"A lot of people think this is a minor problem," said Dr. Rupp, who conducted the study in Omaha. "However, contaminated blood cultures are a big deal. Physicians can be led astray and patients may be harmed by additional tests and unnecessary antimicrobial therapy."

The prospective, controlled study, conducted with 904 patients and 1,808 blood cultures, compared standard procedures to the SteriPath initial specimen diversion device (ISDD) to determine whether blood culture contamination was reduced. The ISDD is a sterile blood collection system that diverts and sequesters the first 1.5 to 2 milliliters of blood – which often carries contaminating skin cells and microbes. This part of the blood is discarded.

Blood culture contamination was significantly reduced through use of the ISDD.

Dr. Rupp said results showed an approximately 88 percent improvement (decrease) in false positives with the ISDD compared to standard phlebotomy procedures.

The results were published online in the journal Clinical Infectious Diseases.

"We were able to decrease the false positive rate significantly through use of this device – from 1.78 percent down to 0.2 percent, which represents an 88 percent reduction," Dr. Rupp said. "The 1.78 percent baseline rate of contamination may seem small, but we should strive to decrease adverse events to the lowest possible level because of the impact to the patient and the burden to our healthcare system. We quite clearly showed the rate of contamination was significantly reduced, and that decrease has a very big impact."

He said contamination rates routinely range from 0.6 percent to 6 percent in U.S. health care institutions.

Costs associated with blood culture contamination per patient case ranged from $1,000 in 1998 to $8,700 in 2009. A more recent study in the United States observed excess charges of $8,720 per contamination event.

"If a midpoint cost estimate of $4,850 is used, and the added cost of the device is not taken into account, it equates to a cost avoidance of $1.8 million per year at our institution alone," Dr. Rupp said. "If the low rate of contamination that we observed in the study, 0.22 percent, was applied to all blood cultures throughout the country, billions of dollars of excess costs could be avoided."
Go to Original
Only Doctors with an M3 India account can read this article. Sign up for free or login with your existing account.
4 reasons why Doctors love M3 India
  • Exclusive Write-ups & Webinars by KOLs

  • Nonloggedininfinity icon
    Daily Quiz by specialty
  • Nonloggedinlock icon
    Paid Market Research Surveys
  • Case discussions, News & Journals' summaries
Sign-up / Log In
x
M3 app logo
Choose easy access to M3 India from your mobile!


M3 instruc arrow
Add M3 India to your Home screen
Tap  Chrome menu  and select "Add to Home screen" to pin the M3 India App to your Home screen
Okay