FDA Press Announcements May 19, 2017

The U.S. Food and Drug Administration authorized use of the Flourish Pediatric Esophageal Atresia Anastomosis, a first–of–its–kind medical device to treat infants up to one year old for esophageal atresia.

“This new device provides a non–surgical option for doctors to treat esophageal atresia in babies born with this condition,” said William Maisel, MD, MPH, acting director of the Office of Device Evaluation in the FDA’s Center for Devices and Radiological Health. “But it is only intended for infants who do not have a tracheoesophageal fistula or who have had the fistula repaired in a prior surgery.”

The device uses magnets to pull the upper and lower esophagus together, closing the gap and allowing food to enter the stomach. It is not for use in infants who also have a tracheoesophageal fistula.

During the procedure to insert the Flourish device, doctors insert two catheters, one through the mouth and one through the stomach. The magnetic ends of the two catheters attract each other, and this attraction pulls the two ends of the esophagus together over several days, closing the gap and forming a connection. Once the catheters are removed, the infant can begin to feed by mouth.

Data supporting the safety and probable benefit of the Flourish device include results from 16 patients who had the Flourish device implanted. In the limited data provided, all of the infants had a successful joining of their esophagus, with no remaining gap, within three to 10 days after receiving the device. However, 13 of the 16 patients developed a complication which caused a narrowing in their esophagus (anastomotic stricture) that required a balloon dilation procedure, a stent or both to repair. Anastomotic strictures also occur from traditional surgery to repair the condition.

The Flourish device should not be used in patients older than one year, or who have teeth, which may damage the oral catheter. The device is also contraindicated in infants who have an existing tracheoesophageal fistula or who have esophageal segments that are more than 4 centimeters apart. Potential complications that may occur when the device is in place include ulceration or tissue irritation around the catheter implanted in the stomach and gum irritation due to pressure from the oral catheter.

Potential long–term complications include gastroesophageal reflux.

The FDA authorized use of the Flourish device to Cook Medical.
Full text available Go to Original
Only Doctors with an M3 India account can read this article. Sign up for free or login with your existing account.
4 reasons why Doctors love M3 India
  • Exclusive Write-ups & Webinars by KOLs

  • Nonloggedininfinity icon
    Daily Quiz by specialty
  • Nonloggedinlock icon
    Paid Market Research Surveys
  • Case discussions, News & Journals' summaries
Sign-up / Log In
x
M3 app logo
Choose easy access to M3 India from your mobile!


M3 instruc arrow
Add M3 India to your Home screen
Tap  Chrome menu  and select "Add to Home screen" to pin the M3 India App to your Home screen
Okay